Noise at Work

Noise at Work Assessment – IBCO Limited, Manchester

Client:

IBCO Limited

Category:

Noise at Work Assessment

Location:

Manchester

IBCO Limited commissioned Peninsular Acoustics to undertake a Noise at Work Assessment for their frozen food packaging factory, to establish the daily noise exposure experienced by their operatives. The assessment was conducted in accordance with current HSE Noise at Work Regulations.

PROJECT SNAPSHOT:

Site Frozen food packaging facility, Manchester
Service Noise at Work Assessment
Facility Scope Large warehouse + separate packaging facility room + office (non-exposed)
Standard Applied Control of Noise at Work Regulations 2005
Reporting Method ANC Registered Report – Field-calibrated sound level meters & dosemeters
Outcome Targeted recommendations on noise control, health surveillance and hearing protection

THE CLIENT:

IBCO Ltd process and package frozen food products from their packaging facility Manchester, the site is compromised of a large warehouse area and smaller packaging facility which is located in a separate room from the main warehouse.
As operatives rotate and share different tasks, they’re exposed to varying noise, a typical job role was developed based on client information and discussions. Furthermore, the smaller office next to the warehouse entrance wasn’t exposed to any significant noise.

OUR APPROACH:

We undertook the survey, measuring all operations in the packaging facility room at the exact location an operative would be working. Additional measurements of typical ambient noise levels were recorded in the packaging facility room to quantify the impact on personnel not operating the noisy machinery at the time but still affected by the noise emitted. The first-floor level breakroom was also considered reference the periods of the day the operatives weren’t exposed to noise.
The noise survey was undertaken with professional sound level meters, dosemeter which were field calibrated. A typical daily work pattern was established following on-site observations and consultations, – workers generally share each task in the processing facility room, rotating between each section of the packaging line. Our calculations assume an 8-hour workday including a 1-hour daily break time, this was used to approximate the typical daily work patterns.

The Regulations:

The Control of Noise at Work Regulations 2005, Health and Safety, 2005 No.1643, sets out ‘action levels’ at which various employers’ obligations are set.
The noise exposure is a function of the noise level to which the operative is exposed and the duration of the exposure. The reference working period in the regulations is eight hours. Noise exposure due to longer working shifts or overtime must be condensed into an eight-hour period and would, therefore, lead to a more onerous assessment.

The Regulations prescribe A-weighted exposure limits in terms of daily or weekly exposure and additional C-weighted peak exposure levels as shown in Table 1

Table 1 Assessment Criteria

Action Value Daily Weekly Exposure or Peak Level
Lower Exposure Action Value (LEAV) 80 dBA 135 dBC
Upper Exposure Action Value (UEAV) 85 dBA 137 dBC
Exposure Limit Value (ELV) 87 dBA 140 dBC

Where an employee is likely to be exposed at or above LEAV, the employer shall make personal hearing protectors available to any employee who asks for them.

Where the employee is likely to be exposed at or above the UEAV, the employer shall ensure that risk from exposure to noise is reduced to the lowest level which is reasonably practicable by establishing and implementing a programme of organisational and technical measures which is appropriate to the activity, including the mandatory provision of hearing protection and marked hearing protection zones.

The employer shall ensure that employees are not exposed to noise above ELV.

KEY FINDINGS:

None of the LCpeak measurements were found to exceed the LEAV of 135 dB(C) for daily peak exposure levels.
The workers were exposed to noise levels at or above the 85 dB LEP,d Upper Exposure Action Value (UEAV).

NOISE AT WORK ASSESSMENT RECOMMENDATIONS:

Following the Noise at Work Assessment, Peninsular Acoustics made several recommendations to Hahn Plastics Ltd, for the employees exposed to the higher noise levels. Recommendations covered noise control options, health surveillance and hearing protection guidance for example.

Project Gallery

A few of our
latest projects

Residential

Sound Insulation test – Seacombe Apartments, The Wirral

Residential

Sound Insulation test – Bastion Point Apartments, Liverpool

Noise at Work

Noise at Work Assessment – IBCO Limited, Manchester

Noise at Work

Noise at Work Assessment – Hahn Plastics Limited, Manchester

Residential

SOR Developments – Example Sound Insulation Test Failure

Commercial

Mersey Engineering Interview Rooms

Residential

Sound Insulation & Floor Covering Design – Trinity Church Square, London

Commercial

Hand-Arm Vibration Assessment – Spraytec Paintworks Limited

Commercial

BS 4142 Noise Assessment – South Road, Liverpool

Commercial

Noise at Work Assessment — JK Francis & Sons Ltd

Residential

Residential Noise Assessment — Barratt & David Wilson Homes

Retail & Leisure

Padel Tennis, Formby