Sound Insulation Testing Site Preparation

Before Sound Insulation Testing is carried out on your development we need to ensure the site conditions are correct.

Classic examples that haunt acoustic consultants; turning up to carry out pre-completion sound insulation testing
to find no doors have been fitted or there is a missing window etc. which make testing impossible.

This blog provides some key information on site readiness for sound insulation testing.

  1. Room Preparation: What “Complete” Means
    Rooms should be available in pairs, either vertically (separated by the party floor) or horizontally (separated by the party wall) as appropriate and must be “complete but unfurnished”.

    This means;
    – All wall and ceiling surfaces complete and skimmed
    – Skirting boards, architraves and covings fitted
    – Kitchen units in place (kitchen/dining areas)
    – Electrical sockets and switches fitted
    – Windows in place, fully closable, with working trickle vents (if fitted)
    – Internal doors in place and fully closable
    – External doors to flats and houses fitted

  2. Keeping the Site Quiet During Testing  
    We require a quiet site, as a few of the measurements we take are very sensitive to noise therefore, the presence of seemingly insignificant noises can cause issues.

    Examples of problematic noises include:
    – Talking in an adjacent room
    – Hammering & grinding
    – Active use of staircase
    – Use of a compressor/generator site vehicles or other external groundworks

    These conditions adversely affect the tests results, especially where very high sound insulation values are being measured. 

    We advise that best arrangement is for all trades to be suspended for the duration of the testing (this can be up to 2 hours for a typical set of tests), or to send workers to another part of the site where their work will not affect the test area. We can, of course, plan to undertake the noise measurements out of normal working hours i.e. during an evening (provided adequate light is available) or over a weekend – Please note that there is normally an additional cost for this. 

  3. Floor Finishes for Impact Testings. 

    – No carpets or laminates — impact testing must be done on the bare floor (chipboard floating floor or concrete floating screed)
    – Pre-installed laminate or timber finishes can be tested, provided they’re permanent
    – Carpets must be rolled back to expose at least half the bare floor
    – Acoustic underlay on a timber floor can stay in place — we test using MDF or plywood under the tapping machine
    – Type 1 floors (solid concrete with soft covering) can be tested directly on the soft covering

  4. Power Supply Requirements

    We require a stable 240 volt power supply should be available in all test rooms to operate the test equipment. If mains power is not yet connected and extension cables aren’t a practicable or safe solution, then we can provide our own portable power supply, subject to availability and we must be made aware prior to site visit.

  5. Access and preparation. 
    Our test engineer selects rooms at their own discretion, unless other arrangements have been made with the building inspector. Please make sure:
    – There’s safe, reasonable access to all areas being tested
    – Rooms are cleared of building materials and tools
    – Floors are swept clean

  6. Health & Safety on Site
    Test areas, staircases and corridors must be free of obstructions, both for safe access with heavy equipment and to avoid trip hazards.
    Our test personnel bring their own PPE (hard hat, safety shoes, hi-vis) and follow all site safety requirements.

  7. Vehicle Access & Parking
    Test equipment is heavy, so we need vehicle access close to the test site. If the vehicle has to be parked further away after equipment drop-off, it should be a short walk. Parking should be arranged by the client.

  8. Plans & Documentation We Need 
    To prepare a full report, it is helpful to have plans of the building showing the room layouts and flat or plot numbers. If known, we also need details of:
    – Floor Constructions
    – Ceiling Construction
    – Wall Construction including densities of plasterboard, blockwork, concrete etc.

For us to issue the final report, we must have:

  • Full names and addresses of the client
  • Details of building/developer
  • Principal contractor